The electrical transformers are
complex in nature. They require synergy of a number of systems and regular
maintenance for operating the transformers at full capacity. But the question
that comes up in the mind is why do the transformers
sometimes fail? When we talk about determining the weak link that caused the
failure in transformer isn’t easy. There are other factors too that might cause
failure and that includes electrical defaults, lightning or even human error.
But now as the maintenance standards have improved, thus, it can help in
preventing the failures and detecting them before any damage becomes permanent
in nature.
The top transformer manufacturers in
India listed the below mentioned reasons for failure of transformers
which are as follows:
·
Aging of the transformers: While judging the cause of failure of the transformer, the age of is
the most important factor that is listed down. If the transformer is old for
more than 15 to 20 years, then the damage may be due to wear and tear.
·
Insulation degradation: Another reason for failure of distribution
transformer is the high temperature. Generally, high temperature of the
transformer weakens the insulation system. The weakening of the system happens
at a rapid speed and it causes overload. Overloading causes overheating and
this causes the cracks in the insulation. If we conduct regular tests and
maintenance, then it will help us in detecting the issue at an early stage.
·
Moisture
absorption: Next reason that can contribute towards the failure in
transformer is moisture in the transformer oil. For detecting this issue,
dissolved gas analysis should be performed regularly so that it can be judged
out whether the oil is contaminated with gas or moisture. It further judges the
type and amount of contamination and would help in determining of the type of
fault.
·
Electrical or mechanical failure: Most of the times, there are damages in the parts or
physical displacement of the transformer. This mostly happens due to a number
of reasons and this includes normal faults and also the seismic activities. By
taking early preventive and maintenance measures can help you in preventing the
mechanical failures. The early diagnosis tests involve Sweet Frequency Response
Testing and induced voltage testing. If the partial discharge is present at the
time of voltage testing, then it shows that there is some sort of mechanical
failure.